型號(hào)
|
A100
|
Bandwidth
|
10Hz…20kHz
|
Crest factor
|
2.25 at rated current
|
Max. current / Max. output voltage
|
No current limit, but maximum output is 4.5 V peak
|
Load impedance
|
≥ 1 M?
|
Influence of Z load impedance
|
≤ 0.1 %/Z, (Z in M?)
|
Output impedance
|
1 k?
|
DC voltage shift at output
|
20 A calibre:≤ 50 mV DC
200 A calibre:≤ 5 mV DC
|
Operating voltage
|
1000 Vrms
|
Influence of adjacent conductor
|
≤ 1 % interference current at 50Hz
(≤ 2 % near click-lock system)
|
Influence of conductor position in loop
|
≤ 1 % (≤ 4 % near click-lock system)
|
Influence of sensor shape
|
≤ 1 % for an oblong shape
|
Battery
|
9 V alkaline battery (NEDA 1604A, IEC 6LR61)
|
Battery life
|
≥ 150 hrs continuous
≥ 1000 x 1 minute measurements
|
Low battery signal
|
Green LED: battery OK
Flashing green LED: low battery
No green LED: battery discharged
|
Overload signal
|
red LED
|
Operating temperature
|
-10 °C to +55°C(maximum temperature for sensor is 90 °C)
|
Storage temperature
|
-40 °C to +70 °C
|
Influence of temperature
|
≤ 0.5 % of output signal per 10 °K
|
Relative humidity for operation
|
0 to 95 % RH with a linear decrease above 35 °C
|
Influence of relative humidity
|
< 0.2 % of output signal from 10 % to 85 % RH
|
Operating altitude
|
0 to 2,000 m
|
Casing protection rating
|
Casing: IP40 (IEC 529)
Flexible sensor: IP65 (IEC 529)
|
Drop test
|
1 m (IEC 68-2-32)
|
Shock resistance
|
100 g (IEC 68-2-27)
|
Vibration resistance (IEC 68-2-6)
|
5/15/5 1.5 mm
15/25/15 1 mm
25/55/25 0.25 mm
|
Self-extinguishing capability
|
Casing, flexible sensor and click-lock
system: UL94 V0
|
Dimensions
|
Casing: 140 x 64 x 28 mm (overall)
Connector lead: 2 m (connects sensor to casing)
Flexible sensor: ? 12 mm ± 0.5 mm
|
Weight
|
Casing: < 200 g
Flexible sensor: approx. 30 g per 10 cm length
|
Bending radius
|
≥ 15 mm
|