尤物爆乳av导航,亚洲欧美乱综合图片区小说区,亚洲精品久久久久久久观小说,亚洲天堂av 在线,一出一进一爽一粗一大视频免费的

柔性電流探頭
型號:Fluke i2500-18 iFlex?
品牌:福祿克/FLUKE

QQ咨詢
微信二維碼

產(chǎn)品功能介紹


產(chǎn)品功能介紹


產(chǎn)品概述

The Fluke iFlex® flexible current probes expand the measurement range of the select Fluke meters to 2500 A AC while 2 Fluke Corporation Fluke i2500-18 iFlex® 柔性電流探頭 https://www.fluke.com.cn/product/附件/電流鉗/fluke-i2500-18-iflex providing the ultimate measurement flexibility. The iFlex® probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.



主要特性

Expands the Measurement Range to 2500 A AC while Providing Increased Display Flexibility, Ability to Measure Awkward Sized Conductors and Improved Wire Access.

CAT IV 600 V, CAT III 1000 V.

7.5 mm Coil Diameter Allows Measurement in Tight Spaces.

Ergonomic Design Allows Easy Operation with One Hand.

1.8 m (6 ft) Cable.

Three-Year Warranty.


產(chǎn)品資料手冊


產(chǎn)品資料手冊

名稱 版本 發(fā)布時間 下載
 Fluke i2500-18 iFlex-技術(shù)參數(shù) -- -- 點擊下載
 Fluke i2500-18 iFlex-參考指南
--
--
點擊下載


標(biāo)配附件


標(biāo)配附件

型號 描述 數(shù)量
Fluke 773
四節(jié) AA 堿性電池(已安裝)、柔軟便攜包、TL75 測試線、AC 72 可拆式線夾、TL 940 迷你型掛鉤測試線、說明書、具有維可牢尼龍搭扣帶的懸掛工具
--


產(chǎn)品規(guī)格


產(chǎn)品規(guī)格

型號 Fluke i2500-18 iFlex®
AC Current

Range:2500 A

Resolution:0.1 A

Accuracy:3% ± 5 digits2

Frequency

Range:500 Hz

Resolution:0.1 Hz

Accuracy:0.5% ± 5 digits

External magnetic field rejection (with cable >10 cm from the coupling) 40 dB
Safety rating CAT III 1000 V, CAT IV 600 V
Distance from Optimum-A

i2500-18:1.4 in (35.6 mm)

Additional iFlex® Error:±0.5%

Distance from Optimum-B

i2500-18:2.0 in (50.8 mm)

Additional iFlex® Error:±1.0%

Distance from Optimum-C

i2500-18:2.5 in (63.5 mm)

Additional iFlex® Error:±2.0%